• Whatsapp No.

    9820129522
    9819574922

  • Email Address

    poojalabequipments@yahoo.in
    karthiknair26@gmail.com

  • Working Hours

    Mon to Sat
    9:30am - 6:00pm

  • Request Quote

Orbital Shaking Incubator

PLE-113 Orbital Shaking Incubator

Pooja Lab's Shaking Incubator is one of its” kinds that included both heating and cooling illumination as optional are available in two versions i.e. non-GMP and GMP choose from different models suitable for various applications in Clinical Laboratory, Pathological Laboratory, Hospitals, Pharmaceuticals, Industrial Chemicals and R & D Labs.

Specifications Model No.
OSI - 100 OSI - 200 OSI - 300
Temperature 10 to 60°C 10 to 60°C 5°C above ambient to 60°C
Accuracy ± 0.5°C ± 0.5°C ± 0.5°C
Setting ± 1°C ± 1°C ± 1°C
Control Soft touch membrane keypad Soft touch membrane keypad Soft touch membrane keypad
Display Digital Digital Digital
Shaking Speed 20 to 200 RPM 20 to 300 RPM 20 to 200 RPM
Control Microprocessor based AC drive Microprocessor based AC drive Microprocessor based AC drive
Motor Maintenance free brushless AC motor with gear head Maintenance free brushless AC motor with gear head Maintenance free brushless AC motor with gear head
Orbit 1" (25.4 mm) fixed 1" (25.4 mm) fixed 1" (25.4 mm) fixed
Refrigeration 0.4 hp 0.4 hp None
Insulation PUF PUF Glass Wool
Doors Metallic insulated fitted at top Metallic insulated fitted at top Perspex fitted at top
External Dimensions 762 W x 710 D x 875 H mm approx plus door height 762 W x 710 D x 875 H mm approx plus door height 762 W x 710 D x 875 H mm approx plus door height
Capacity to hold Flasks 24 Nos of 50/100 ml or 16 Nos of 250/500 ml or 9 Nos of 1000/2000 ml 24 Nos of 50/100 ml or 16 Nos of 250 or 500 ml or 9 Nos of 1000/2000 ml 24 Nos of 50/100 ml or 16 Nos of 250 or 500 ml or 9 Nos of 1000/2000 ml

Optional Accessories:
  • Imported Microprocessor based auto turing PID digital controller with dual display for SET value and PROCESS value, which gives temperature accuracy of 0.2°C.
  • Centronic interface for keeping hard copies of Date, Time and Temp (Set value and actual value) on 80 Col. dot matrix printer supplied without printer (This facility is available only on with imported controller).
  • Safety alarm system for warming incase of temperature overshoot 230V output for extemal hooter.
  • PC interface communication card with RS 485 to use with the above imported control system (Hardware).
  • 21 CFR part 11 compliance window based software for data management complete with RS 485 for temperature.
  • 80 col. dot-matrix printer with stand.
  • Illumination for OSI-100 & 200 with timer and lotus clamps with screw.
  • Illumination control with digital display.
  • Maximum lightinsensitivity is 3500 lux.
Pre-installation requirements:
  • Stabilized 230V 50Hz AC single-phase 15 amps power supply with MCB and proper earthing within the radius of one meter from the installation.
  • To be installed in an air-condition or in a cross ventilated, dust free and clean environment with free space around. Room temperature should be below 30°C)
  • Zero level flooring and Floor level drainage within the radius of one meter from the installation.

Orbital Shaking Incubator Manufacturer in Mumbai